Shanghai VKEY Biotechnologies Co.,Ltd.
Shanghai VKEY Biotechnologies Co.,Ltd.
Email Us

KeyTec® TR-FRET PD1/PD-L1 Binding Assay kit

Quick replication of product information

KeyTec® TR-FRET PD1/PD-L1 Binding Assay kit

Size:

Price: $ Inquire

CAT.: A1090003S

A1090003S_1.1
A1090003S_1.1
A1090003S_1.1
A1090003S_1.1
A1090003S_1.1
A1090003S_1.1

• Easy to Use: A homogeneous assay - just follow the 'add-incubate-measure' process
• High S/B: The kit provides a superior window

• Easy to Use: A homogeneous assay - just follow the 'add-incubate-measure' process
• High S/B: The kit provides a superior window

Size:
1,000 tests
10,000 tests
Price:
$ Inquire
CAT.:
A1090003S
Delivery:
Available in Stock
Price:
$ Inquire
CAT.:
A1090003L
Delivery:
Available in Stock
KeyTec® TR-FRET PD1/PD-L1 Binding Assay kit
1,000 tests
1,000 tests
10,000 tests
CAT.: A1090003S
$ Inquire $ Inquire
Overview
Performance
Protocols
Components
Notices
Related Products

Overview

KeyTec® TR-FRET PD1/PD-L1 Binding Assay Kit is designed for the quantitative measurement of the interaction between human PD1 and PD-L1 proteins. This kit provides a Tag1-PD-L1 protein, a Tag2-PD1 protein, an anti-tag1 antibody labeled with KeyTec® TR-FRET Solar Eu*1 (mAb anti-Tag1 - Solar Eu) ,an anti-tag2 antibody labeled with KeyTec® TR-FRET LA*2 (mAb anti-Tag2 - LA) and other detection reagents. These components enable the high-throughput screening of small molecule inhibitors, peptides, or antibody blockers.

This assay is based on a competitive immunoassay method using KeyTec® TR-FRET technology, offering a simple, rapid, highly specific and sensitive, as well as reproducible detection process. The principle, outlined in Figure 1:

The binding of the mAb anti-Tag1 - Solar Eu, the Tag1-PD-L1 protein, the mAb anti-Tag2 - LA and the Tag2-PD1 protein brings the TR-FRET donor and acceptor into close proximity, enabling resonance energy transfer (RET) upon excitation and generating a TR-FRET signal. Compounds, peptides, or antibodies that block the PD1/PD-L1 interaction will cause a decrease in the TR-FRET signal.

 

*1  KeyTec® TR-FRET Solar Eu: TR-FRET Donor

*2  KeyTec® TR-FRET HX: TR-FRET Acceptor


KeyTec® TR-FRET PD1/PD-L1 Binding Assay kit A1090003S

Performance

KeyTec® TR-FRET PD1/PD-L1 Binding Assay kit A1090003S

Protocols

Components

CAT. Description Size
A1090003S KeyTec® TR-FRET PD1/PD-L1 Binding Assay kit 1,000 tests

The tests are sufficient in a 384-well microplate assay format, with 20 μL per well.
  •  1 vial(80 μL/vial) Tag1-PD-L1 (50X)
  •  1 vial(80 μL/vial) Tag2-PD1 (50X)
  •  1 vial(50 μL/vial) Anti-Tag1–Solar Eu (100X)
  •  1 vial(50 μL/vial) Anti-Tag2–LA (100X)
  •  1 bottle(50 mL/bottle)Binding Assay Diluent Buffer
  •  1 bottle(30 mL/bottle)Solar Eu Detection Buffer

Notices

Certificate of Analysis Limitations Storage Conditions
LOT. For research use only -60℃ or below

-60℃ or below

Overview

KeyTec® TR-FRET PD1/PD-L1 Binding Assay Kit is designed for the quantitative measurement of the interaction between human PD1 and PD-L1 proteins. This kit provides a Tag1-PD-L1 protein, a Tag2-PD1 protein, an anti-tag1 antibody labeled with KeyTec® TR-FRET Solar Eu*1 (mAb anti-Tag1 - Solar Eu) ,an anti-tag2 antibody labeled with KeyTec® TR-FRET LA*2 (mAb anti-Tag2 - LA) and other detection reagents. These components enable the high-throughput screening of small molecule inhibitors, peptides, or antibody blockers.

This assay is based on a competitive immunoassay method using KeyTec® TR-FRET technology, offering a simple, rapid, highly specific and sensitive, as well as reproducible detection process. The principle, outlined in Figure 1:

The binding of the mAb anti-Tag1 - Solar Eu, the Tag1-PD-L1 protein, the mAb anti-Tag2 - LA and the Tag2-PD1 protein brings the TR-FRET donor and acceptor into close proximity, enabling resonance energy transfer (RET) upon excitation and generating a TR-FRET signal. Compounds, peptides, or antibodies that block the PD1/PD-L1 interaction will cause a decrease in the TR-FRET signal.

 

*1  KeyTec® TR-FRET Solar Eu: TR-FRET Donor

*2  KeyTec® TR-FRET HX: TR-FRET Acceptor


KeyTec® TR-FRET PD1/PD-L1 Binding Assay kit A1090003L

Performance

KeyTec® TR-FRET PD1/PD-L1 Binding Assay kit A1090003L

Protocols

Components

CAT. Description Size
A1090003L KeyTec® TR-FRET PD1/PD-L1 Binding Assay kit 10,000 tests

The tests are sufficient in a 384-well microplate assay format, with 20 μL per well.
  •  1 vial(800 μL/vial) Tag1-PD-L1 (50X)
  •  1 vial(800 μL/vial) Tag2-PD1 (50X)
  •  1 vial(500 μL/vial) Anti-Tag1–Solar Eu (100X)
  •  1 vial(500 μL/vial) Anti-Tag2–LA (100X)
  •  1 bottle(200 mL/bottle)Binding Assay Diluent Buffer
  •  1 bottle(120 mL/bottle)Solar Eu Detection Buffer

Notices

Certificate of Analysis Limitations Storage Conditions
LOT. For research use only -60℃ or below

-60℃ or below

Related Immunity & Cancer

VKEY-BIO Provides High-Quality Life Science Reagents For You!
Cooperative Development
(+86)-021-5835-6939
Phone Number (+86)-021-5835-6939
marketing@vkeybio.com
Email marketing@vkeybio.com
Location
Location Floor 3, Building 2, Lane 898, Halei Road, Pudong New Area, Shanghai, China
Name *
Telephone
Email *
Company
Message *