Shanghai VKEY Biotechnologies Co.,Ltd.
Shanghai VKEY Biotechnologies Co.,Ltd.
Email Us

KeyTec® TR-FRET Human SMARCA2 Binding Kit

Quick replication of product information

KeyTec® TR-FRET Human SMARCA2 Binding Kit

Size:

Price: $

CAT.: A1090013D

KeyTec® TR-FRET  Human SMARCA2 Binding Kit
KeyTec® TR-FRET  Human SMARCA2 Binding Kit
KeyTec® TR-FRET  Human SMARCA2 Binding Kit
Size:
100 tests
500 tests
5,000 tests
Price:
$
CAT.:
A1090013D
Delivery:
Available in Stock
Price:
$
CAT.:
A1090013S
Delivery:
Available in Stock
Price:
$
CAT.:
A1090013L
Delivery:
Available in Stock
Sample Request
KeyTec® TR-FRET Human SMARCA2 Binding Kit
100 tests
100 tests
500 tests
5,000 tests
CAT.: A1090013D
$ $ $
Overview
Performance
Protocols
Components
Notices
Related Products

Overview

The KeyTec® TR-FRET Human SMARCA2 Protein Binding Assay Kit is designed for screening ligands or inhibitors of wild‑type human SMARCA2 protein. This kit is a competitive immunoassay developed using KeyTec® TR‑FRET technology, offering advantages such as simple and rapid operation, high specificity, high sensitivity, and excellent reproducibility.


The principle is as follows: Solar Eu1‑conjugated anti‑Tag1 antibody specifically recognizes Tag1‑SMARCA2 protein, while HX2‑conjugated streptavidin (Streptavidin‑HX) recognizes biotinylated Bromodomain Ligand. When SMARCA2 protein binds to the Bromodomain Ligand, Solar Eu and HX are brought into close proximity, enabling energy resonance transfer between the donor and acceptor upon external light excitation. The degree of binding between the Bromodomain Ligand and SMARCA2 is determined by measuring the signal intensity at 665 nm. In the absence of inhibitors or competing ligands, the signal is at its maximum; as the concentration of added inhibitors or ligands increases, the signal gradually decreases. The TR‑FRET signal intensity is inversely proportional to the affinity of the inhibitor or ligand.


A1090013_1.1

Performance

A1090013_1.2

                                                        Standard curve

A1090013_1.3

Validation results with different final concentrations of DMSO

A1090013_1.4

Validation results in buffer systems with different pH values

Components

CAT. Description Size
A1090013D KeyTec® TR-FRET Human SMARCA2 Binding Kit 100 tests


  •  1 vial 5 µL/vial SMARCA2/4 binding standard 1

  •  1 vial 8 µL/vial Tag1 - SMARCA2

  •  1 vial 8 µL/vial Bromodomain Ligand

  •  1 vial 5 µL/vial mAb anti - Tag1 - Solar Eu

  •  1 vial 5 µL/vial Streptavidin - HX

  •  2 vials 2 mL/vial SMARCA2/4 Binding Assay Diluent Buffer(pH 8.0)

  •  1 vial 2 mL/vial SMARCA2/4 Detection Buffer(pH 8.0)


Notices

Certificate of Analysis Limitations Storage Conditions
LOT. For research use only -60℃ or below

-60℃ or below

Overview

The KeyTec® TR-FRET Human SMARCA2 Protein Binding Assay Kit is designed for screening ligands or inhibitors of wild‑type human SMARCA2 protein. This kit is a competitive immunoassay developed using KeyTec® TR‑FRET technology, offering advantages such as simple and rapid operation, high specificity, high sensitivity, and excellent reproducibility.


The principle is as follows: Solar Eu1‑conjugated anti‑Tag1 antibody specifically recognizes Tag1‑SMARCA2 protein, while HX2‑conjugated streptavidin (Streptavidin‑HX) recognizes biotinylated Bromodomain Ligand. When SMARCA2 protein binds to the Bromodomain Ligand, Solar Eu and HX are brought into close proximity, enabling energy resonance transfer between the donor and acceptor upon external light excitation. The degree of binding between the Bromodomain Ligand and SMARCA2 is determined by measuring the signal intensity at 665 nm. In the absence of inhibitors or competing ligands, the signal is at its maximum; as the concentration of added inhibitors or ligands increases, the signal gradually decreases. The TR‑FRET signal intensity is inversely proportional to the affinity of the inhibitor or ligand.


KeyTec® TR-FRET  Human SMARCA2 Binding Kit A1090013S

Performance

A1090013_1.2

                                                        Standard curve

A1090013_1.3

Validation results with different final concentrations of DMSO

A1090013_1.4

Validation results in buffer systems with different pH values

Components

CAT. Description Size
A1090013S KeyTec® TR-FRET Human SMARCA2 Binding Kit 500 tests


  •  1 vial 10 µL/vial SMARCA2/4 binding standard 1

  •  1 vial 40 µL/vial Tag1 - SMARCA2

  •  1 vial 40 µL/vial Bromodomain Ligand

  •  1 vial 25 µL/vial mAb anti - Tag1 - Solar Eu

  •  1 vial 25 µL/vial Streptavidin - HX

  •  1 bottle 20 mL/bottle SMARCA2/4 Binding Assay Diluent Buffer(pH 8.0)

  •  1 bottle 20 mL/bottle SMARCA2/4 Detection Buffer(pH 8.0)


Notices

Certificate of Analysis Limitations Storage Conditions
LOT. For research use only -60℃ or below

-60℃ or below

Overview

The KeyTec® TR-FRET Human SMARCA2 Protein Binding Assay Kit is designed for screening ligands or inhibitors of wild‑type human SMARCA2 protein. This kit is a competitive immunoassay developed using KeyTec® TR‑FRET technology, offering advantages such as simple and rapid operation, high specificity, high sensitivity, and excellent reproducibility.


The principle is as follows: Solar Eu1‑conjugated anti‑Tag1 antibody specifically recognizes Tag1‑SMARCA2 protein, while HX2‑conjugated streptavidin (Streptavidin‑HX) recognizes biotinylated Bromodomain Ligand. When SMARCA2 protein binds to the Bromodomain Ligand, Solar Eu and HX are brought into close proximity, enabling energy resonance transfer between the donor and acceptor upon external light excitation. The degree of binding between the Bromodomain Ligand and SMARCA2 is determined by measuring the signal intensity at 665 nm. In the absence of inhibitors or competing ligands, the signal is at its maximum; as the concentration of added inhibitors or ligands increases, the signal gradually decreases. The TR‑FRET signal intensity is inversely proportional to the affinity of the inhibitor or ligand.


KeyTec® TR-FRET  Human SMARCA2 Binding Kit A1090013L

Performance

A1090013_1.2

                                                        Standard curve

A1090013_1.3

Validation results with different final concentrations of DMSO

A1090013_1.4

Validation results in buffer systems with different pH values

Components

CAT. Description Size
A1090013L KeyTec® TR-FRET Human SMARCA2 Binding Kit 5,000 tests


  •  1 vial 50 µL/vial SMARCA2/4 binding standard 1

  •  1 vial 400 µL/vial Tag1 - SMARCA2

  •  1 vial 400 µL/vial Bromodomain Ligand

  •  1 vial 250 µL/vial mAb anti - Tag1 - Solar Eu

  •  1 vial 250 µL/vial Streptavidin - HX

  •  1 bottle 200 mL/bottle SMARCA2/4 Binding Assay Diluent Buffer(pH 8.0)

  •  1 bottle 120 mL/bottle SMARCA2/4 Detection Buffer(pH 8.0)


Notices

Certificate of Analysis Limitations Storage Conditions
LOT. For research use only -60℃ or below

-60℃ or below

Related Immunity & Cancer

VKEY-BIO Provides High-Quality Life Science Reagents For You!
Cooperative Development
(+86)-021-5835-6939
Phone Number (+86)-021-5835-6939
marketing@vkeybio.com
Email marketing@vkeybio.com
Location
Location Floor 3, Building 2, Lane 898, Halei Road, Pudong New Area, Shanghai, China
Name *
Telephone
Email *
Company
Message *
Sample Request
We look forward to your order and to jointly advancing the development of life science research. Product Name KeyTec Enhanced Luciferase Detection Kit
Reason For Application *
Corporate OR Research Group *
Address *
Name *
Telephone *
Mailbox *
Verification Code *