Shanghai VKEY Biotechnologies Co.,Ltd.
Shanghai VKEY Biotechnologies Co.,Ltd.
Email Us

KeyTec® TR-FRET Human IL12/IL12R-β1 Binding Assay Kit

Quick replication of product information

KeyTec® TR-FRET Human IL12/IL12R-β1 Binding Assay Kit

Size:

Price: $ Inquiry

CAT.: A1070105D

KeyTec® TR-FRET Human IL12/IL12R-β1 Binding Assay Kit
KeyTec® TR-FRET Human IL12/IL12R-β1 Binding Assay Kit
KeyTec® TR-FRET Human IL12/IL12R-β1 Binding Assay Kit
Size:
100 tests
500 tests
5,000 tests
Price:
$ Inquiry
CAT.:
A1070105D
Delivery:
Available in Stock
Price:
$ Inquiry
CAT.:
A1070105S
Delivery:
Available in Stock
Price:
$ Inquiry
CAT.:
A1070105L
Delivery:
Available in Stock
Sample Request
KeyTec® TR-FRET Human IL12/IL12R-β1 Binding Assay Kit
100 tests
100 tests
500 tests
5,000 tests
CAT.: A1070105D
$ Inquiry $ Inquiry $ Inquiry
Overview
Performance
Protocols
Components
Notices
Related Products

Overview

The KeyTec® Human TR-FRET IL12/IL12R-β1 Binding Assay Kit is designed for high-throughput screening of small-molecule inhibitors, peptides, or antibodies that block the interaction between IL12 and IL12R-β1 proteins. This kit utilizes KeyTec® TR-FRET technology, offering advantages such as simplicity, speed, and high accuracy.


As illustrated in the principle diagram below, the KeyTec® TR-FRET Solar Eu®¹-labeled anti-Tag 1 antibody specifically recognizes IL12 protein carrying Tag 1, while the KeyTec® TR-FRET LA®²-labeled Streptavidin recognizes biotinylated IL12R-β1 protein (AVI-Biotin). When IL12 binds to IL12R-β1, Solar Eu and LA are brought into close proximity, enabling energy resonance transfer between the donor and acceptor upon external light excitation. The interaction level between IL12 and IL12R-β1 is determined by measuring the signal intensity at a specific wavelength (665 nm). Consequently, compounds, peptides, or antibodies that disrupt the IL12–IL12R-β1 interaction will result in a decrease in TR-FRET signal.


A1070105_1.1

Performance

A1070105_1.2

Standard Blocker Validation Results

A1070105_1.3

Test Results of Different Blockers

Components

CAT. Description Size
A1070105D KeyTec® TR-FRET Human IL12/IL12R-β1 Binding Assay Kit 100 tests

       •  1 vial of 20 µL/vial IL12 / IL12R-β1 binding standard

       •  1 vial of 8 µL/vial Tag1-IL12

       •  1 vial of 8 µL/vial IL12R-β1-Biotin

       •  1 vial of 5 µL/vial Anti-Tag1–Solar Eu

       •  1 vial of 5 µL/vial Streptavidin–LA

       •  2 vials  2 mL/vial Binding Assay Diluent Buffer

       •  1 vial  2 mL/vial Solar Eu Detection Buffer


Notices

Certificate of Analysis Limitations Storage Conditions
LOT. For research use only -60 ℃及以下

-60 ℃及以下

Overview

The KeyTec® Human TR-FRET IL12/IL12R-β1 Binding Assay Kit is designed for high-throughput screening of small-molecule inhibitors, peptides, or antibodies that block the interaction between IL12 and IL12R-β1 proteins. This kit utilizes KeyTec® TR-FRET technology, offering advantages such as simplicity, speed, and high accuracy.


As illustrated in the principle diagram below, the KeyTec® TR-FRET Solar Eu®¹-labeled anti-Tag 1 antibody specifically recognizes IL12 protein carrying Tag 1, while the KeyTec® TR-FRET LA®²-labeled Streptavidin recognizes biotinylated IL12R-β1 protein (AVI-Biotin). When IL12 binds to IL12R-β1, Solar Eu and LA are brought into close proximity, enabling energy resonance transfer between the donor and acceptor upon external light excitation. The interaction level between IL12 and IL12R-β1 is determined by measuring the signal intensity at a specific wavelength (665 nm). Consequently, compounds, peptides, or antibodies that disrupt the IL12–IL12R-β1 interaction will result in a decrease in TR-FRET signal.



A1070105_1.1

Performance

A1070105_1.2

Standard Blocker Validation Results

A1070105_1.3

Test Results of Different Blockers

Components

CAT. Description Size
A1070105S KeyTec® TR-FRET Human IL12/IL12R-β1 Binding Assay Kit 500 tests

       •  1 vial of 50 µL/vial IL12 / IL12R-β1 binding standard

       •  1 vial of 40 µL/vial Tag1-IL12

       •  1 vial of 40 µL/vial IL12R-β1-Biotin

       •  1 vial of 25 µL/vial Anti-Tag1–Solar Eu

       •  1 vial of 25 µL/vial Streptavidin–LA

       •  1 bottle  50 mL/bottle Binding Assay Diluent Buffer

       •  1 bottle  30 mL/bottle Solar Eu Detection Buffer


Notices

Certificate of Analysis Limitations Storage Conditions
LOT. For research use only -60 ℃及以下

-60 ℃及以下

Overview

The KeyTec® Human TR-FRET IL12/IL12R-β1 Binding Assay Kit is designed for high-throughput screening of small-molecule inhibitors, peptides, or antibodies that block the interaction between IL12 and IL12R-β1 proteins. This kit utilizes KeyTec® TR-FRET technology, offering advantages such as simplicity, speed, and high accuracy.


As illustrated in the principle diagram below, the KeyTec® TR-FRET Solar Eu®¹-labeled anti-Tag 1 antibody specifically recognizes IL12 protein carrying Tag 1, while the KeyTec® TR-FRET LA®²-labeled Streptavidin recognizes biotinylated IL12R-β1 protein (AVI-Biotin). When IL12 binds to IL12R-β1, Solar Eu and LA are brought into close proximity, enabling energy resonance transfer between the donor and acceptor upon external light excitation. The interaction level between IL12 and IL12R-β1 is determined by measuring the signal intensity at a specific wavelength (665 nm). Consequently, compounds, peptides, or antibodies that disrupt the IL12–IL12R-β1 interaction will result in a decrease in TR-FRET signal.



KeyTec® TR-FRET Human IL12/IL12R-β1 Binding Assay Kit A1070105L

Performance

A1070105_1.2

Standard Blocker Validation Results  

A1070105_1.3

Test Results of Different Blockers

Components

CAT. Description Size
A1070105L KeyTec® TR-FRET Human IL12/IL12R-β1 Binding Assay Kit 5,000 tests

       •  2 vials of 50 µL/vial IL12 / IL12R-β1 binding standard

       •  1 vial of 400 µL/vial Tag1-IL12

       •  1 vial of 400 µL/vial IL12R-β1-Biotin

       •  1 vial of 250 µL/vial Anti-Tag1–Solar Eu

       •  1 vial of 250 µL/vial Streptavidin–LA

       •  1 bottle  200 mL/bottle Binding Assay Diluent Buffer

       •  1 bottle  120 mL/bottle Solar Eu Detection Buffer


Notices

Certificate of Analysis Limitations Storage Conditions
LOT. For research use only -60 ℃及以下

-60 ℃及以下

Related Cytokine - Receptor Binding

VKEY-BIO Provides High-Quality Life Science Reagents For You!
Cooperative Development
(+86)-021-5835-6939
Phone Number (+86)-021-5835-6939
marketing@vkeybio.com
Email marketing@vkeybio.com
Location
Location Floor 3, Building 2, Lane 898, Halei Road, Pudong New Area, Shanghai, China
Name *
Telephone
Email *
Company
Message *
Sample Request
We look forward to your order and to jointly advancing the development of life science research. Product Name KeyTec Enhanced Luciferase Detection Kit
Reason For Application *
Corporate OR Research Group *
Address *
Name *
Telephone *
Mailbox *
Verification Code *