TR-FRET Assay for Quantitative Measurement of Human IL2 Protein in Supernatant

•  Easy to Use: A homogeneous assay - just follow the 'add-incubate-measure' process
•  High Sensitivity: A Wide linear range from 134 pg/mL to 20,000 pg/mL
•  Only 16 µL of the sample, no dilution required, highly suitable for HTS Assays

TR-FRET Assay for Quantitative Measurement of Human IL6 Protein in Supernatant

•  Easy to Use: A homogeneous assay - just follow the 'add-incubate-measure' process
•  High Sensitivity: A Wide linear range from 134 pg/mL to 20,000 pg/mL
•  Only 16 µL of the sample, no dilution required, highly suitable for HTS Assays

TR-FRET Assay for Quantitative Measurement of Human IL6 Protein in Supernatant

•  Easy to Use: A homogeneous assay - just follow the 'add-incubate-measure' process
•  High Sensitivity: A Wide linear range from 134 pg/mL to 20,000 pg/mL
•  Only 16 µL of the sample, no dilution required, highly suitable for HTS Assays

Size:
100 tests
1,000 tests
10,000 tests
Price:
$ Inquire
CAT.:
A1070002D
Delivery:
Available in Stock
Price:
$ Inquire
CAT.:
A1070002S
Delivery:
Available in Stock
Price:
$ Inquire
CAT.:
A1070002L
Delivery:
Available in Stock
Sample Request
KeyTec® TR-FRET Human IL2 Detection kit
100 tests
100 tests
1,000 tests
10,000 tests
CAT.: A1070002D
$ Inquire $ Inquire $ Inquire
Overview
Performance
Protocols
Components
Notices
Related Products

Overview

KeyTec® TR-FRET Human IL2 Detection Kit can be used to measure the expression level of Human IL2 in samples such as cell culture supernatants. This kit is a sandwich immunoassay developed based on KeyTec® TR-FRET technology, featuring simplicity, rapidity, high specificity, high sensitivity, and good reproducibility.

The basic principle of this method is illustrated in the figure below. A pair of specific antibodies are separately conjugated with the fluorescence energy donor Solar Eu and the fluorescence energy acceptor LA. When the two antibodies bind to different epitopes of the Human IL2 protein, energy resonance transfer occurs between the donor and acceptor upon excitation by an external light source. The level of Human IL2 protein can be determined by detecting the signal intensity at a specific wavelength (665 nm).


678924e29272b2a3b0106251d4c85f64.png

Performance

KeyTec® TR-FRET Human IL2 Detection kit A1070002D

标准曲线结果展示

KeyTec® TR-FRET Human IL2 Detection kit A1070002D

不同基质溶液测试结果

Components

CAT. Description Size
A1070002D KeyTec® TR-FRET Human IL2 Detection kit 100 tests

       •  1 vial 5 µL/vial mAb anti-IL2- Solar Eu

       •  1 vial 5 µL/vial mAb anti-IL2- LA

       •  1 vial 50 µL/vial Human IL2 Standard

       •  2 vials 2 mL/vial Cytokine Diluent Buffer

       •  1 vial 2 mL/vial Cytokine Detection Buffer


Notices

Certificate of Analysis Limitations Storage Conditions
LOT. For research use only -60 ℃及以下

-60 ℃及以下

Overview

KeyTec® TR-FRET Human IL2 Detection Kit can be used to measure the expression level of Human IL2 in samples such as cell culture supernatants. This kit is a sandwich immunoassay developed based on KeyTec® TR-FRET technology, featuring simplicity, rapidity, high specificity, high sensitivity, and good reproducibility.

The basic principle of this method is illustrated in the figure below. A pair of specific antibodies are separately conjugated with the fluorescence energy donor Solar Eu and the fluorescence energy acceptor LA. When the two antibodies bind to different epitopes of the Human IL2 protein, energy resonance transfer occurs between the donor and acceptor upon excitation by an external light source. The level of Human IL2 protein can be determined by detecting the signal intensity at a specific wavelength (665 nm).


678924e29272b2a3b0106251d4c85f64.png


Performance

A1070002_1.1


标准曲线结果展示


A1070002_1.3


不同基质溶液测试结果

Components

CAT. Description Size
A1070002S KeyTec® TR-FRET Human IL2 Detection kit 1,000 tests

       •  1 vial 50 µL/vial mAb anti-IL2- Solar Eu

       •  1 vial 50 µL/vial mAb anti-IL2- LA

       •  2 vials (Lyophilized) Human IL2 Standard

       •  1 bottle 20 mL/bottle Cytokine Diluent Buffer

       •  1 bottle 10 mL/bottle Cytokine Detection Buffer


Notices

Certificate of Analysis Limitations Storage Conditions
LOT. For research use only -60 ℃及以下

-60 ℃及以下

Overview

KeyTec® TR-FRET Human IL2 Detection Kit can be used to measure the expression level of Human IL2 in samples such as cell culture supernatants. This kit is a sandwich immunoassay developed based on KeyTec® TR-FRET technology, featuring simplicity, rapidity, high specificity, high sensitivity, and good reproducibility.

The basic principle of this method is illustrated in the figure below. A pair of specific antibodies are separately conjugated with the fluorescence energy donor Solar Eu and the fluorescence energy acceptor LA. When the two antibodies bind to different epitopes of the Human IL2 protein, energy resonance transfer occurs between the donor and acceptor upon excitation by an external light source. The level of Human IL2 protein can be determined by detecting the signal intensity at a specific wavelength (665 nm).


678924e29272b2a3b0106251d4c85f64.png



Performance

A1070002_1.1

标准曲线结果展示

A1070002_1.3

不同基质溶液测试结果

Components

CAT. Description Size
A1070002L KeyTec® TR-FRET Human IL2 Detection kit 10,000 tests

       •  1 vial 500 µL/vial mAb anti-IL2- Solar Eu

       •  1 vial 500 µL/vial mAb anti-IL2- LA

       •  2 vials (Lyophilized) Human IL2 Standard

       •  1 bottle 50 mL/bottle Cytokine Diluent Buffer

       •  1 bottle 50 mL/bottle Cytokine Detection Buffer


Notices

Certificate of Analysis Limitations Storage Conditions
LOT. For research use only -60 ℃及以下

-60 ℃及以下

Related Cytokine Detection

VKEY-BIO Provides High-Quality Life Science Reagents For You!
Cooperative Development
(+86)-021-5835-6939
Phone Number (+86)-021-5835-6939
marketing@vkeybio.com
Email marketing@vkeybio.com
Location
Location Floor 3, Building 2, Lane 898, Halei Road, Pudong New Area, Shanghai, China
Name *
Telephone
Email *
Company
Message *
Sample Request
We look forward to your order and to jointly advancing the development of life science research. Product Name KeyTec Enhanced Luciferase Detection Kit
Reason For Application *
Corporate OR Research Group *
Address *
Name *
Telephone *
Mailbox *
Verification Code *